Array 3.0 Pro - A Series - MDC
ARRAY 3.0Pro-A Series MDC adalah solusi Modular Data Center (MDC) generasi baru dari Santak yang mengintegrasikan catu daya & distribusi, kontrol suhu, rak server, kabel, hingga sistem monitoring ke dalam satu modul tunggal. Dipadukan dengan sistem PEC series, teknologi pemantauan lingkungan dinamis buatan Santak, solusi ini memberikan pemantauan tanpa henti terhadap daya, suhu, kelembapan, rembesan air, asap, hingga kamera pengawas. Dengan desain modular terintegrasi, efisiensi hingga 98%, serta pemasangan cepat karena komponen inti telah dirakit & diuji di pabrik, seri ini ideal untuk data center, colocation, hyperscale, ruang server perusahaan, institusi pendidikan, fasilitas medis, instansi pemerintahan, dan lembaga keuangan.
Kapasitas
Cocok untuk:
- Data Center, Colocation, Hyperscale
- Ruang Server Perusahaan Enterprise
- Perbankan, Telekomunikasi, dan Sistem Siaran
- Transportasi & Sistem Keamanan Publik
- Fasilitas Kesehatan, Medis, dan Lab
- Pendidikan, Sekolah, dan Kampus
Beli di:
Fully Modular & Rack-Mounted
UPS 40kVA per Modul, hingga 200kVA
Bersertifikasi iF Design Award 2023
Cooling Air-Cooled hingga 60kW
Efisiensi hingga 98% (ECO Mode)
Rack Standar 42U, Beban 3.000kg
Keamanan Akses Berlapis
Monitoring PEC Series Real-Time
| UPS | ||||
|---|---|---|---|---|
| Power input type | 380/400/415VAC, 50/60Hz, 3P+N+PE | |||
| Lightning protection | Class C, In=20kA | |||
| Input power factor | >0.99 @ 20-100% load, >0.95 @ 10-20% load | |||
| Input switch | Single input or ATS dual input | |||
| UPM | 40kVA per module | |||
| UPS chassis capacity | 120kVA/200kVA optional | |||
| Output power factor | 1 (ambient temperature ≤ 35°C) | |||
| Overall efficiency | Up to 98% | |||
| Output power distribution | Mains power output branches: 63A/3P cooling unit power distribution circuit * 6 + Backup 63A/3P circuit * 1 + Backup 16A/1P circuit * 3 UPS output branches: 32A/1P IT power distribution circuit * 48 |
|||
| Power distribution cabinet | ||||
| Power input type | 380/400/415Vac, 50/60Hz, 3P+N+PE | |||
| Input switch | Single or dual MCCB: 125A/160A/250A/400A | |||
| Lightning protection | Class C, In=20kA | |||
| Output branch | 20/32/48/60 | |||
| Monitor | Precision power distribution rack: total power consumption monitoring of both main and branch circuits; Standard power distribution rack: power consumption monitoring of the main circuit | |||
| Communication | RS485 | |||
| Rack & PDU | ||||
| Rack size | H: 2000mm, 42U W: 600/800mm D: 1200mm | |||
| Perforation ratio | Front single-hinged door, rear swing mesh door, with a perforation ratio of 80% | |||
| Color | RAL9005 | |||
| Static load | 3000kg | |||
| Optional accessory | Side panels, blind plates, trays, L-shaped brackets, horizontal cable organizers, etc. | |||
| PDU | Input: Single-phase 16A/32A/63A; Output: GB socket 16/24 standard port | |||
| Aisle system | ||||
| End door | Automatic sliding doors, manual sliding doors | |||
| Ambient lighting | Three-color alarm ambient lighting | |||
| Skylight | 300/600/800mm fixed skylights, 600/800mm flip-up skylights, optional one-piece skylight reset assembly | |||
| Lighting | LED energy-saving lamp tubes, with an illuminance of over 300 Lx. | |||
| Strong and weak current cable tray | Each rack equipped with two strong and weak cable trays at the top | |||
| Cross-row cable tray | One at each end of the aisle | |||
| Cooling unit | ||||
| Type | Air-cooled direct expansion | |||
| Cooling capacity | 12.5/25/30/40/50/60kW | |||
| Power input | 380V/3P, 50Hz | |||
| Air supply method | Horizontal air supply | |||
| Refrigerant | R410A | |||
| Commonly used optional accessory | Extension component, low-temperature components, condensate pumps, etc. | |||
| Monitoring system | ||||
| Monitoring controller | PEC-500: 1U rack-mounted PEC-300: 0U 10-inch all-in-one screen, 4*RS232 serial port (sharing signals with PORT1-2 of RS485), 12*RS485 independent serial ports, 1*HDMI (4K*2K resolution at 24Hz), 1*VGA (maximum resolution: 2560*1200), 8*DI, 4*DO wet contact, 2*DO dry contact, built-in 4G SMS module |
|||
| Display screen | 10/21.5/43 inch | |||
| Environmental monitoring | Temperature and humidity sensors, smoke detectors, water immersion sensors, smart access control systems, audible and visual alarms, high-definition cameras, etc. | |||
| Power equipment | Integrated UPS rack, cooling unit, power distribution cabinet, UPS, battery monitoring device, etc. | |||